当气瓶没有气体时,机器工作实现实时报警,可以使用本功能
一.气压报警器的选型:
需使用无源的常开/常闭类,因此可选择膜片式可调压力开关,建议使用型号[QPM11NO常开]
如您使用的报警器为有源高低电平输出,请使用继电器转接为无源信号
二.报警逻辑:
在焊接动作开始后,按照预定设置的电平来检测信号接口一的1/2脚的电平
三.安装方案:
1.气压报警器应接在气阀出气端
2.两根无源信号线接在信号接口一的1/2脚
3.如使用型号为常闭,则系统设置里面的气压报警电平为高电平有效,否则设置为低
四.附件
When the gas cylinder is empty, the machine will trigger a real-time alarm to indicate this condition, and this function can be utilized
I. Selection of barometric pressure alarm:
A passive normally open/closed type is required, so a diaphragm-type adjustable pressure switch can be selected. It is recommended to use the model [QPM11NO normally open]
If the alarm you are using has active high and low level outputs, please use a relay to convert it into a passive signal
II. Alarm logic:
After the welding action begins, detect the voltage level of pin 1/2 of signal interface 1 according to the preset voltage level
III. Installation Plan:
1. The air pressure alarm should be connected to the air outlet end of the air valve
2. Connect two passive signal lines to pin 1/2 of signal interface 1
3. If the used model is normally closed, the air pressure alarm level in the system settings should be set to high level effective; otherwise, it should be set to low
4 attachment